© Copyright 2000, Sea Gull Lighting
2 - 1525-CUL-English
CH-545
1
2
3
Unpack and inspect fan carefully to
be certain all contents are included.
Turn off power at breaker box to
avoid possible electrical shock.
Use outlet box suitable for fan
support. Secure outlet box directly to
the buildin g structure using ceiling
joist screws. Outlet box must support
35 lbs.
4
Install mounting bracket to outlet
box in ceiling using the screws
provided with the outlet box and
washers.
TOOLS REQUIRED
Phillips Screwdriver Wire Cutters Pliers Step Ladder
6
Clevis
Pin
Set
Screws
Cotter
Pin
5
Install downrod into rubber canopy
and ceiling canopy. Feed motor
wires through downrod/canopy
assembly.
Insert downrod into motor yoke.
Next, insert clevis pin through yoke
and downrod and secure with cotter
pin. (see inset) Tighten both yoke
set screws to further secure
downrod.
Safety Tips
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
READ AND SAVE THESE INSTRUCTIONS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards(ANSI/NFPA
70-1993), including fire-rated construction.
Use this unit only in the manner intended by the manufacurer. If you have any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor
on one side of the outlet box and ungrounded conductor on the other side of the outlet box.
Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a
tag, to the service panel.
Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet
from the floor to the trailing edge of the blade.
To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support.
(Mounting must support at least 35 lbs.)
Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet box.
To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
NEVER place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating
equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NEPA), and the
American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a
tag, to the service panel.
NOTE--FOR OUTDOOR FANS ONLY: Suitable for use in wet locations when installed in a GFCI protected branch circuit.
INSTALLATION